I-chromatograph yedijithali ye-hplc
Isiteshi se-I.Pump: Iphampu ye-quaternary L-3245
1, I-Max Pressure: 9000 psi (62Mpa)
2, Izinga lokugeleza:0.001 -10.000 mL/min(ukwenyuka 0.001mL/min)
3, Ukunemba kwezinga lokugeleza:≤0.06% RSD(ASTM)
4, Ukunemba kwezinga lokugeleza: ± 0.2%
I-5, i-Pressure Pulsation:≤1%
6, Ukunemba kweGradient: ± 0.5%
7, I-Gradient Repeatablity:≤0.1%
8, Ukugeza ku-inthanethi: Okujwayelekile, Okuphakeme/okuphakathi/Ijubane eliphansi
9, Isiteshi se-Degassing: Isiteshi esine-Degassing, i-480ul/Channel
II.Isiteshi sephampu: Iphampu yokufaka ingcindezi ephezulu kanambambili L-3220
1, I-Max Pressure: 9000 psi (62Mpa)
2, Izinga lokugeleza:0.001 -10.000 mL/min(ukwenyuka 0.001mL/min)
3, Ukunemba kwezinga lokugeleza:≤0.06% RSD(ASTM)
4, Ukunemba kwezinga lokugeleza: ± 0.2%
I-5, i-Pressure Pulsation:≤1%
6, Ukunemba kweGradient: ± 0.5%
7, Ukugeza ku-inthanethi: ≤0.1%
8, Ukugeza ku-inthanethi: Okujwayelekile, Okuphakeme/okuphakathi/Ijubane eliphansi
III.Isiteshi sephampu: L-3210 Ipompo yokufaka ye-Isotonic
1, I-Max Pressure: 9000 psi (62Mpa)
2, Izinga lokugeleza:0.001 -10.000 mL/min(ukwenyuka 0.001mL/min)
3, Ukunemba kwezinga lokugeleza:≤0.06% RSD(ASTM)
4, Ukunemba kwezinga lokugeleza: ± 0.2%
I-5, i-Pressure Pulsation:≤1%
I.Sampler :Manual Sampler, Rodin 7725I
1, inaliti yomjovo we-HAMILTON 100-litre flat-head:
II.Sampler:Autosampler L-3320
1, Imodi yesampula: Iluphu egcwele / iluphu eyingxenye / μL Ukuthatha
2, ivolumu ye-Loop: 100 μL (ukulinganisa okujwayelekile)
3, Ukuphindaphinda kwesampula: Umjovo wendandatho ogcwele:RSD≤0.3% Umjovo wengxenye:RSD≤0.5% umjovo wenkampani yenethiwekhi ye-Microliter:RSD≤1%
4, isampula yevolumu: 2 Standard 48-bit isibambi ibhodlela 1.5 ML isampula ibhodlela (Optional 96 Hole Plate, 384 hole plate)
5, Ukungcola Okuphambanayo: ~ 0.005%
6, Umugqa:0.9999
7, Ubukhulu: 6000psi (customizable)
I.Ikholomu kuhhavini L-3400
1, Ibanga leTemp:Ambient+5℃-70℃
2, Ukunemba Kwesikhashana: ± 1.0℃
3, Ukuzinza Kwesikhashana: ± 0.1℃
4, Umthamo wekholomu: Ikholomu eyodwa engu-250 mm (Ingakwazi ukuhlonywa insika yokuvikela engu-10mm)
Umtshina
I.I-Detector: umtshina we-diode array
1, Ububanzi be-Wavelength: 190-640 nm
2, Umthombo wokukhanya: isibani se-deuterium
3, Umkhawulokudonsa we-Spectral: 4.8 nm
4, Ukunemba kwe-Wavelength: ±1 nm
5 , Umsindo: ± 1.0 × 10-5 AU (JJG) ± 0.6 × 10-5 AU (ASTM)
6 Rift Ukusebenza: 0.5 × 10-3 AU / Hr
7, Ukunemba kwe-Wavelength: 0.1 nm
8 , Ububanzi bomugqa:> 2.0AU (ASTM) Umsindo: ± 1.0 × 10-5 AU (JJG) ± 0.6 × 10-5 AU (ASTM)
9、Isilinganiso esikhulu samasampula: iziteshi eziyi-12, 100Hz;i-spectrum ephelele, i-100Hz
10, Ukumelana nokucindezela kokugeleza kweseli: 1200PSI
11, Indlela yokubona yokugeleza kweseli: 10mm
12, Ubuncane bokugxila kokutholwa: 2×10-8 g/mL
13, Ivolumu yeseli yokugeleza: 12ul
I-14, Ukulinganisa kwe-Wavelength: ukuphakama kwesici sesibani se-mercury kanye nesihlungi esakhelwe ngaphakathi se-holmium oxide
II.Umtshina:UVVIS Detector L-3500
1, Ubude begagasi: 190-800 nm
2, Umthombo wokukhanya: Isibani se-Deuterium nesibani se-Tungsten
3, Ububanzi beSpectral: 8nm
4, Ukunemba kwe-Wavelength: ±1 nm
5, Umsindo: ± 0.35 × 10-5 AU (ASTM)
6 、 Ukusebenza: 1 × 10-4 AU / Hr
7, Ukunemba kwe-Wavelength: 0.2 nm
8, Ububanzi Bomugqa: > 2.5AU (ASTM)
9, Izinga Lesampula Eliphezulu: 100Hz
10, Flow cell pressure: 1200PSI
11, Umzila wokukhanya kweseli: 10mm
12, Umkhawulo wokutholwa: 4×10-9 g/mL
III.Umtshina: RI Detector L-3560
1, Ingcindezi enkulu emuva: 50 kPa
2, Indlela yokulinganisa: Uhlobo lokuphambuka
3, Ibanga le-Reflective Index: 1.00–1.75
4, Ibanga lomugqa: 600 µRIU
5, Umsindo: 2.5 nRIU (impendulo: 1.5 isekhondi)
6, Uziro ozenzakalelayo: uziro ozenzakalelayo ogcwele
7, Ibanga le-Offset: 0 kuya ku-500 mV (isinyathelo esingu-10 mV)
8、 Okuphumayo kwe-Integrator (Ukuzwela): DC 0 ukuya ku-1 V (2 mV/µRIU, 8 mV/µRIU)
9, Imbobo yokuxhumana: RS232C
10、 Ubukhulu nesisindo: H 150 × W 260 × D 450 (mm), cishe.12 kg
IV.Umtshina:Umtshina we-Fluorescent
1, Ukuzwela: (Isilinganiso sesignali-kuya-nomsindo se-Water Raman peak singaphezu kuka-1200)
2, Umthombo wokukhanya: Isibani se-Xenon
3, Isikhathi sokusetshenziswa kombuzo nokuphathwa kwelogi ngomsebenzi we-VP
4, Ukuphendula Okusheshayo kanye nemvamisa yesampula (100hz, 10ms) isekela ukuhlaziywa kwe-UFLC
5, Faka esikhundleni isibani kanye nethangi lokujikeleza kusukela ngaphambili kwensimbi ngaphandle kokulungiswa kwesikhundla
I-V.Detector:I-Evaporative light scattering detector (ELSD)Rittun L-3535
Umthombo wokukhanya: I-LED 470nm
Isici Sokuthola: I-Ultra yempilo ende ye-silicon photodiode
Ibanga lokushisa: RT-100℃
Ukusetshenziswa Kwegesi: <3.0L/min
Imodi yokulawula: I-Cryogenic shunt
Ikhanda lesifutho: HPLC, CC
1, Ukusebenza kokulawula: thobela i-FDA 21 CFR Ingxenye 11 / GMP / GLP imininingwane;
2, Ukusebenziseka kalula: isikhombikubona sokuqhafaza sokuqapha, singabamba isimo semishini nganoma yisiphi isikhathi, kulula futhi kulula ukuyisebenzisa;
3, Ukucubungula idatha: umsebenzi onamandla wokucubungula idatha, ukuhlinzeka ngemisebenzi ehlukahlukene ebalulekile kanye nezindlela zokubala;
4, Imisebenzi ecebile: ububanzi obuphakeme obuzenzakalelayo, i-algorithm ye-threshold ezenzakalelayo, ukutholwa kwedatha okuguquguqukayo, i-algorithm yokulungisa okuzenzakalelayo ukuze kuzuzwe umphumela omuhle kakhulu wokuhlanganisa;
5, Ukuphathwa komsebenzisi: umsebenzi wokuphatha umsebenzisi onamandla futhi ophelele, amalungelo okufinyelela angasethwa ukuze kube lula ukuphathwa, futhi izimvume ezahlukene zingasethwa ngokuvumelana nezidingo zangempela zocwaningo lwesayensi nokufundisa;
Qaphela:
Lonke iqoqo lamathuluzi, okuhlanganisa izindawo zokusebenza, lihlangabezana nezidingo ze-GMP / GLP kanye nemithetho ye-FDA CFR 21 ingxenye 11!